Read MoreQuick View
Alat Distilasi
SPESIFIKASI :
- Skala laboratorium,
- terbuat dari kaca/gelas yang tahan terhadap panas
- bahan kimia korosif,terdiri dari labu distilasi 250 mL,dan pendingin/kondensor Leibig
Read MoreQuick View -
Read MoreQuick View
Atomic Absorption Spectrophotometer
SPESIFIKASI :
- Optical system Wavelength range: 190-900nm
- Grating mark density: approx. 1800 lines
- Spectral bandwidth: approx. 0.2nm, 0.4nm, 1.0nm, 2.0nm, for multiple auto-switching
- Wavelength precision: ±0.2nm
- Wavelength repeatability: approx. 0.05nm
- Baseline drift: approx. 0.002 A / 30 min
- Detectors: Wide spectral range photomultiplier tube
- Spectral bandwidth deviation: Copper lamp approx. 324.7nm 0.2nm and bandwidth deviation within ±0.01nm – Light source system
- Lamp holders: Four lamp holders for auto-switching
- Lamp power supply mode: 400Hz square wave pulse
- Atomization system Concentration (Cu): 0.025μg/ml/1% LOQ (Cu): approx. 0.006μg/mL
- Burner: approx. 100mm, singleslit titanium metal burner, which is air-cooled pre-mixed type
- Precision: RSD≤0.8%
- Measuring methods: Airacetylene flame method and atomic absorption method for hydride generator
Read MoreQuick View -
Read MoreQuick View
Auto Soxhlet Fat Extractor
SPESIFIKASI :
- Power Requirement: approx. 1000W
- Warming time: approx. 10 min
- Recycle system: Automatic Recycle rate: ≥80%
- Temperature control range: Room temperature-100°C
- Difference: Even heating and automatic recycling, automatic soaking and extraction, save working time
Read MoreQuick View -
Read MoreQuick View
Bernoulli’s Theorem Demonstration
SPESIFIKASI :
- Manometer range 0-300 mm
- number of manometer tubes are 8
Read MoreQuick View -
Read MoreQuick View
Centrifugal Pump Demonstration Unit
SPESIFIKASI :
- Small scale centrifugal pump unit, comprising of water reservoir, pump, control valves and interconnecting pipework.
- Equipped with electronic sensors for pump head pressure, suction, flow rate, and water temperature, also computer system operational.
Read MoreQuick View -
Read MoreQuick View
Centrifuge
SPESIFIKASI :
- Max. Speed: approx. 5000 rpm
- Max. RCF: approx. 4390 xg
- Swing Rotor: approx. 8x50ml (4000 r/min RCF 2810 xg)
- Timer Range: 0 ~ 99 min
- Motor: Brushless Motor
- Power Supply: AC 220V 50Hz 10A
- Noise: ≤65dB
Read MoreQuick View -
Read MoreQuick View
Evaporator Apparatus
SPESIFIKASI :
- Laboratory evaporation system : Rising or falling film single/ double effect Temperature controlled pre-heat stage Manual control console Completed with adjustable recirculation on each evaporation stage, integral USB interface, vacuum pump, condenser and condensate vessel.
Read MoreQuick View -
Read MoreQuick View
Filtration Apparatus
SPESIFIKASI :
- Standard a plate and frame batch filter.
- Electrical circuits Console : pump motor control and display panel.
- Interface device and eduacational software
Read MoreQuick View -
Read MoreQuick View
Flow Meter Demonstration
SPESIFIKASI :
- Manometer range : 0 -440 mm
- Number of manometer tubes : 8 Completed with orifice plate dan venturi
Read MoreQuick View -
Read MoreQuick View
Fluid Mixing Studies
SPESIFIKASI :
- Vessel : approx. 25 L, made from clear materials, drain tap, removable baffles.
- Agitation variable speed : approx.. 0 – 500 rpm.
- Impellers : various different design ± 8.
- Power : approx.. 0 – 75 watt.
Read MoreQuick View -
Read MoreQuick View
Free and Forced Vortex
SPESIFIKASI :
- Tank diameter : ± 245 mm
- Height to overflow point : ± 180 mm
- Completed with orifice, forced vortex measuring probes, and pitot tubes.
Read MoreQuick View -
Read MoreQuick View
Gas Chromatography
SPESIFIKASI :
- Column Oven Temperature operating range : Higher than the room temperature of 5ºC-450ºC
- Temperature setting : 1ºC; programmed heating rate 0.1ºC
- Maximum heating speed : approx. 120ºC/min.
- Temperature stability : It will be 0.01ºC, when the environment temperature changes 1ºC.
- Programmed temperature steps : 7 steps
- Column loss can be compensated (dual channel column)
- Injectors :
- Various injector available: packed column injectors, split/splitless capillary column injectors or cool on-column injectors.
- Detectors :
- FID Max temperature control : approx. 400ºC
- LOD : ≤ 5 x 10-12 g/s [n-C16]
- Linear dynamic range : ≥107
- Drift : ≤ 5 x 10-13 A/30min
- Noise : ≤2 x 10-13 A
- TCD Max using temperature : approx. 400ºC
- Sensitivity : ≥10000mv.ml/mg [nC16]
- Linear dynamic range : ≥104
- Drift : ≤ 10 0uV/30min
- Noise : ≤20 uA FPD
- Max using temperature : 250ºC LOD : ≤2 x 10-13g/s(P), ≤5 x 10- 11g/s (S)
- Linear dynamic range : ≥103(P),≥102 (S)
- Noise : ≤2 x 10-12 A Drift : ≤4 x 10-11 A/30min
- ECD
- Max using temperature : approx. 350ºC
- Drift : ≤5 0uV/30min
- LOD : ≤1 x 10-14 g/ml (y-666)
- Linear dynamic range : ≥104
- Noise : ≤20uA
- NPD : Max using temperature : approx. 400ºC LOD : ≤5 x 10-13g/s(P),≤1 x 10-12 g/s (N)
- Noise : ≤4 x 10-13 A
- Drift : ≤2.5 x 10-12 A/30min
- Linear dynamic range : ≥103(P),≥103 (N)
- PDHID
- LOD : ≤ 5 ppb
- Include Nitrogen Hydrogen and Air Generator
Read MoreQuick View